Setup Diagram

SHORT CONTROL

Enables/Disables Short Control.

CROSS MODE

Toggles between Input Off/Input Remain. Input remain will allow input to remain on when switching modes.

CROSS RANGE

Toggles between Input Off/Input Remain. Input remain will allow input to remain on when switching ranges.

RSF DETECT
Enable/Disable Remote Sense Fault Protection.

TRIGGER SOURCE

Trigger source and the triggering method Selection – Refer to table below

.

TRIGGER

SOURCE

TRIGGER INPUT

EXT_TRG_IN *TRG

Command

Ethernet

TRIG:IMM

Command

Front

Panel

EXTERNAL

O X

X

O

O

BUS

X O

X

O

O

ETHERNET

X X

O

X

X

HOLD

X X

X

O

O

TABLE 3.1 TRIGGER INPUT SOURCE

Important Notes:

1.

X = Non-functional & O = Functional

2.

EXT_TRG_IN & ETHERNET triggers input through the respective interface connections

3.

*TRG and TRIG:IMM are SCPI commands

Current

Shunt

Function

Generator

+ INPUT

-INPUT

+S

-S

EXT GND

eLOAD

EXT PRG

DMM

DUT

DMM

10V

• AC Signal • -1V

EXTERNAL PROGRAMMING SETUP

AC + DC