AMETEK PLA-PLW User Manual
Page 59

MENU FUNCTION
The MENU function allows the user to set the different system configurations such as GPIB, Stepping, Max/Min setting,
Protection, and Calibration. The vast array of features and configurations allow the eLOAD to accommodate different
situations or testing configurations. The Local/Menu function is the start of the tree structure, which enables the user to
branch.
Press MENU key:
* (Use
43 to select the next menu setting then press ENTER key to enter the selected menu).
* (Use CLEAR key to back space or to correct the wrong value).
A: Load Control Menu
- press ENTER key:
*Turn the encoder
43 to select the next menu setting then press ENTER key to enter the selected menu.
* (Use CLEAR key to back space or to correct the wrong value).
1.
STEP PARAM.------- press ENTER key, use
43 to select number of Step COUNT then press ENTER. (0 Î
infinite)
2.
MEASURE SENSE--press ENTER key, use
43 to select LOCAL / REMOTE sense then press ENTER.
3.
PORT0 ----------------press ENTER key, use
43 to enables or disables digit port the press ENTER.
4.
EXT. CONTROL-----press ENTER key, use
43 to select ON / OFF then press ENTER.
5.
SHORT CONTROL--press ENTER key, use
43 to select ON / OFF then press ENTER.
6.
CROSS MODE-------press ENTER key, use
43 to select INPUT OFF / INPUT REMAIN then press ENTER.
7.
CROSS RANGE----- press ENTER key, use
43 to select INPUT OFF / INPUT REMAIN then press ENTER.
8.
TRIGGER-------------press ENTER key, use
43 to select Source (Held, BUS, EXTERNAL, ETHERNET) /
DELAY (in milli-second), then press ENTER.
9.
PROTECTION--------press ENTER key,
1. OV PROTECTION--------------press ENTER key, input the STATE/LIMIT/DELAY then press ENTER.
2. UV PROTECTION--------------press ENTER key, input the STATE/LIMIT/DELAY then press ENTER.
3. OC PROTECTION--------------press ENTER key, input the STATE/LIMIT/DELAY then press ENTER.
4. UC PROTECTION--------------press ENTER key, input the STATE/LIMIT/DELAY then press ENTER.
5. OP PROTECTION--------------press ENTER key, input the STATE/LIMIT/DELAY then press ENTER.
6. UP PROTECTION--------------press ENTER key, input the STATE/LIMIT/DELAY then press ENTER.
7. V-ON CONTROL--------------press ENTER key, input the STATE/V-ON THRESHOLD then press ENTER.
10. MAX/MIN LIMIT---press ENTER key,
1.
MAX VOLTAGE--------press ENTER key, input the maximum voltage then press ENTER
1: STEP PARAM.
432: MEASURE SENSE 43 3: PORT 0 434: EXT. CONTROL 43 5: SHORT
CONTROL
43 6: CROSS MODE 43 7: CROSS RANGE 43 8: TRIGGER 439: PROTECTION 43
10: MAX/MIN LIMIT
4311: CAL PARAM. 43 12: OSCILLATE 43 13: BOOT INPUT
1: OV PROTECTION
432: UV PROTECTION 43 3: OC PROTECTION 43 4: UC PROTECTION
43 5: OP PROTECTION 436: UP PROTECTION 43 7: V-ON CONTROL
1: MAX VOLTAGE
432: MIN VOLTAGE 43 3: MAX CURRENT 43 4: MIN CURRENT 43 5:
MAX RESISTOR
436: MIN RESISTOR 43 7: MAX POWER 43 8: MIN POWER
(A: LOAD CONTROL
43 B: PROFILE 43 C: DISPLAY 43 D: SYSTEM 43
E: AUTHENTICATE)
3-5