AMETEK PLA-PLW User Manual
Page 123

1) eLOAD input Off
2) DUT Output Off (During Delay)
3) Open External Contactor/Relay
Local Control
MENU
ÎLOAD CONTROLÎ INPUT CONTACTOR Î CONTROL Î DISABLE
Î PORT0 + @ ON
Î PORT0 - @ ON
Î DELAY
Î 50ms ~ 500ms
Remote Programming
[SOURce:]INPut:CONtactor
This command configures the INPUT CONTACTOR Mode
Command Syntax
INPut:CONtactor
Parameters
1: DISABLE | 2: PORT0+ @ ON | 3: PORT0+ @ ON
Query Syntax
INPut:CONtactor?
Returned Parameters
1 | 2 | 3
[SOURce:]INPut:CONtactor:DELay
This command configures the INPUT CONTACTOR Mode
Command Syntax
INPut:CONtactor:DELay
Parameters
50 ~ 500ms
Query Syntax
INPut:CONtactor:DELay?
Returned Parameters
50 ~ 500ms
3. Ultra-low CC & CP and Ultra-high CR Ranges (Optional Feature)
Project requirements are dynamic and over a long time span and often times it may need
high-current applications one day and ultra-low current applications the next. AMREL
eLOAD offers an Ultra-low range CC and CP mode and a Ultra-high range CR mode
utilizing a unique dual-shunt design which provides precise, accurate, high-resolution and
repeatable measurements in thousands of Amps and down to tens of Amps in a single box.
The purchase of a single system over the lifetime of the project will yield incredible cost
savings in ROI and satisfy dynamic application demands.
Constant Current Ultra Low (CCUL) Range –
x
Programming Accuracy: .05% of Setting + .05% of CCUL Max Current
x
Read back and Measurement: .05% of Reading + .05% of CCUL Max Current
x
Resolution: 14 Bits
Constant Power Ultra Low (CPUL) Range –
x
Programming Accuracy: 1% of Setting + .1% of CPUL Max Power
x
Read back and Measurement: .05% of Reading + .1% of CPUL Max Power
x
Resolution: 14 Bits
Constant Resistance Ultra High (CRUH) Range –
x
Programming Accuracy: Please refer to Specifications
C-3