1) eLOAD input Off
2) DUT Output Off (During Delay)
3) Open External Contactor/Relay

Local Control

MENU

ÎLOAD CONTROLÎ INPUT CONTACTOR Î CONTROL Î DISABLE

Î PORT0 + @ ON
Î PORT0 - @ ON

Î DELAY

Î 50ms ~ 500ms

Remote Programming

[SOURce:]INPut:CONtactor

This command configures the INPUT CONTACTOR Mode

Command Syntax

INPut:CONtactor

Parameters

1: DISABLE | 2: PORT0+ @ ON | 3: PORT0+ @ ON

Query Syntax

INPut:CONtactor?

Returned Parameters

1 | 2 | 3

[SOURce:]INPut:CONtactor:DELay

This command configures the INPUT CONTACTOR Mode

Command Syntax

INPut:CONtactor:DELay

Parameters

50 ~ 500ms

Query Syntax

INPut:CONtactor:DELay?

Returned Parameters

50 ~ 500ms

3. Ultra-low CC & CP and Ultra-high CR Ranges (Optional Feature)

Project requirements are dynamic and over a long time span and often times it may need
high-current applications one day and ultra-low current applications the next. AMREL
eLOAD offers an Ultra-low range CC and CP mode and a Ultra-high range CR mode
utilizing a unique dual-shunt design which provides precise, accurate, high-resolution and
repeatable measurements in thousands of Amps and down to tens of Amps in a single box.
The purchase of a single system over the lifetime of the project will yield incredible cost
savings in ROI and satisfy dynamic application demands.

Constant Current Ultra Low (CCUL) Range –

x

Programming Accuracy: .05% of Setting + .05% of CCUL Max Current

x

Read back and Measurement: .05% of Reading + .05% of CCUL Max Current

x

Resolution: 14 Bits

Constant Power Ultra Low (CPUL) Range –

x

Programming Accuracy: 1% of Setting + .1% of CPUL Max Power

x

Read back and Measurement: .05% of Reading + .1% of CPUL Max Power

x

Resolution: 14 Bits

Constant Resistance Ultra High (CRUH) Range –

x

Programming Accuracy: Please refer to Specifications

C-3