4 asymmetric loop test, Asymmetric loop test – Xtramus NuBAR-1000 V1.4 User Manual

Page 51

background image

50

E-mail: [email protected]

Website: www.

X

tramus.com

XTRAMUS TECHNOLOGIES

®

Tx Byte: Transmitted data bytes.

Y

: Received Counter at Lord NuBAR-1000 that is transmitted from Servant NuBAR-1000 in

symmetric loop test.

Rx Rate: Receive rate from ongoing test stream generated from Servant NuBAR-1000.

Z

: Rx Maximum Rate: Maximum receive rate from ongoing test stream generated from

Servant NuBAR-1000.

Rx Packet: Received packet counts

Rx Byte: Received data bytes.

CRC Error: CRC error packet counts found from received packet

Packet Loss: Packet loss counts found from Servant to Lord.

A2

: Packet Loss (Both): Packet loss counts found from both Lord to Servant and Servant to

Lord.

A3

: Close this Window

5.4.4 Asymmetric Loop Test

Click

at

Shortcut Key bar.

For the symmetrical loop test above, Lord and Servant send symmetrical test stream to each

other for the test. For this asymmetric loop, the test stream and transfer rate between local Lord

NuBAR-1000 and remote Servant NuBAR-1000 is different.