beautypg.com

4 for network infrastructure, 5 for mesh network, For network infrastructure – Xtramus NuBAR-1000 V1.4 User Manual

Page 23: For mesh network

background image

22

E-mail: [email protected]

Website: www.

X

tramus.com

XTRAMUS TECHNOLOGIES

®

4.1.4 For Network Infrastructure

To test the transmission quality between two network locations that is connected by multiple

network equipments such as Ethernet Switches, Network Server, connect two ends of the

network device to a pair of NuBAR-1000. The figure below illustrates the transmission test

between location A and B.

Note: NuBAR-1000 is test equipment of layer 2 packet. Devices that can not forward layer 2

(MAC based) packet are not suitable for the test. Network such as Internet runs layer 3 protocols

is not suitable for the test. It is applicable for ADSL test for cable wiring business. The connection

between CO (central office) and the CPE (ADSL modem) apply layer 2 Ethernet.

4.1.5 For Mesh Network

As the rotary function switch introduced above, NuBAR-1000 is able to do mesh connection test.
Lord sends test packets to the 1

st

Servant, then the 1

st

Servant forward packets to 2

nd

Servant.

Repeat the procedure until the packets returns to Lord finally.
The application below applies to six locations of network infrastructure.

A

B