Check the system status before starting test.
In normal condition, Power, Servant is ON and Battery is blinking if charging is processing.
Note: To operate different function mode via Functional Rotary Switch, the role of NuBAR-1000
become Lord. Then the Servant LED is OFF and Lord mode is activated.
Connect hardware with network cable
Connect the network cable depending on the different test scenario as described in 4.1
Connect a pair of NuBAR-1000
Press the Tx Test button to test the network. Speed is ON (ON: 1000Mbps connection; Mild
blinking (2Hz): 100Mbps connection; Slow blinking (1Hz): 10Mbps connection)
Start Test
Press the Run / Stop button to start the test,
(connect) is ON and wait for the stop
automatically.
4.3 Test Result
The result of the test is shown on the LED indicator instantly.
Type
Label
LED
Description
Test result
CRC
ON
CRC Error is found during the test
Blinking
Keep blinking if CRC error packets are
received continually.
Tx loss
ON
Packet loss is found when test stream
is transmitted from local side to
remote side during the test
Rx loss
ON
Packet loss is found when test stream
is received from remote side to local
side during the test.
Fail
ON
Result of the test is failed.