beautypg.com

Xtramus NuBAR-1000 V1.4 User Manual

Page 15

background image

14

E-mail: [email protected]

Website: www.

X

tramus.com

XTRAMUS TECHNOLOGIES

®

4

BERT Loopback
Test

Lord sends BERT (Bit Error Rate Test) pattern (long packets, PRBS
2^31-1) to Servant and returns with switched DA / SA (destination /
source MAC address) and recalculated CRC for Loopback test.

Rotary function switch location

Lord NuBAR-1000: 4

Servant NuBAR-1000: 0

5

Mesh Loop Test

Lord send mesh connection request to all Servants. There are
maximum 5 Servants for this mesh connection test.
Then Lord sends test packets to the 1

st

Servant, then the 1

st

Servant

forward packets to 2

nd

Servant. Procedure is repeated until the final

Servant returns packets to Lord.
When test is done, all of them synchronize the result.

Rotary function switch location

Lord NuBAR-1000: 5

Servant NuBAR-1000: 0. The sequnece of acknowledge from
servants decides the sequence of servant.

6

Web Access

Get IP from DHCP server in the LAN and then access web server in
Internet to download a specified file from Internet for test purpose.