4. Procedure of Operation

This chapter tells user how to use NuBAR-1000 in your test site.

4.1 Hardware Connection

4.1.1 For Self-Test

Before the real test, operator can connect the two devices directly by network cable (Cat. 5e or

above is suggested) for functional check.

4.1.2 For Single DUT

Without high cost desktop test equipment, the compact size NuBAR-1000 is able to do Ethernet

network test easily.

The test streams run through the two ports that join the test. If there are more than two port that

need to join the test simultaneously, other advanced model can fit user's requirement. Please

contact with distributor of Xtramus.

4.1.3 For Cable Wiring

To wiring a network cable in office or building, NuBAR-1000 is convenient for data transmission

test. Do this test to insure the transmission quality for real environment. To test the cable inside

the building, connect two sides of the cable to a pair of NuBAR-1000. If the test is passed, it also

performs well in real condition by real network device.

Servant

Lord

Cat. 5e or above
network cable

Lord

Servant