3 test time rotary switch, Test time rotary switch, Test time rotary – Xtramus NuBAR-1000 V1.4 User Manual
Page 19: Switch
18
E-mail: [email protected]
Website: www.
X
tramus.com
XTRAMUS TECHNOLOGIES
®
MAC address, one is for transmission of test data and the other is for negotiation and
communication. DUT/NUT has to register totally 4 MAC addresses in its MAC address table
for a pair of NuBAR-1000.
3.1.3 Test Time Rotary Switch
There are two 16 scales Test Time Rotary Switch for configuration of duration for each test.
It is for the configuration of test duration each time. Duration in seconds is configured in 2 hex
mode rotary switches.
16 scales rotary switch: 0~9, A = 10, B = 11. C = 12, D = 13, E=14, F=15
User can calculate the result from Windows calculator (Start Programs Accessories
Calculator). For example, 12 seconds
Input 12 in Decimal mode
Then click Hexadecimal, then the answer is C. Rotate the switch to "0" "C" for duration of 12
seconds
Scale: No. 0~9,
A~F
Current
Setting
Scale: No. 0~9,
A~F
16 x 16 = 256
Seconds (maximum)