beautypg.com

3 test time rotary switch, Test time rotary switch, Test time rotary – Xtramus NuBAR-1000 V1.4 User Manual

Page 19: Switch

background image

18

E-mail: [email protected]

Website: www.

X

tramus.com

XTRAMUS TECHNOLOGIES

®

MAC address, one is for transmission of test data and the other is for negotiation and
communication. DUT/NUT has to register totally 4 MAC addresses in its MAC address table
for a pair of NuBAR-1000.

3.1.3 Test Time Rotary Switch

There are two 16 scales Test Time Rotary Switch for configuration of duration for each test.

It is for the configuration of test duration each time. Duration in seconds is configured in 2 hex

mode rotary switches.

16 scales rotary switch: 0~9, A = 10, B = 11. C = 12, D = 13, E=14, F=15

User can calculate the result from Windows calculator (Start  Programs  Accessories 

Calculator). For example, 12 seconds

Input 12 in Decimal mode

Then click Hexadecimal, then the answer is C. Rotate the switch to "0" "C" for duration of 12

seconds

Scale: No. 0~9,

A~F

Current
Setting

Scale: No. 0~9,

A~F

16 x 16 = 256

Seconds (maximum)