 Select the same ID for a pair of NuBAR-1000

For a test that is work by a pair of NuBAR-1000, the ID number of the two NuBAR-1000 has to

be the same. The default ID of NuBAR-1000 is "00". , means Lord accepts any reply from

Servant if NuBAR-1000 is in Lord mode and Servant replies any request from Lord if

NuBAR-1000 is in Servant mode.

Rotate two ID rotary switches to other value, such as "01" for two NuBAR-1000.

Lord NuBAR-1000 Servant NuBAR-1000

 Configure the test duration for a single test

Test duration is configured by hexadecimal mode that is described at 3.1.3 Test Time Rotary

Switch

For 1 minutes (60 seconds) test

Lord NuBAR-1000 Servant NuBAR-1000

4.2.2 Start the Test Procedure

 Power ON both Lord and Servant NuBAR-1000 from power switch.

Note: To fit the compact size of the NuBAR-1000, the power switch is tiny. To prevent damage of

this switch, please slide the switch carefully or push it via the attached ceramic screwdriver.

0

1

0

1

3

C

Configuration for

Servant NuBAR-1000

is not required

Turn On