beautypg.com

Dataman 48XP User Manual

Page 62

background image

62

Poor contact at pin %s!

The DATAMAN-48XP does an insertion test before

programming/erasing etc. any device.

This message indicates that the socket may be dirty; the device may

have been damaged etc. Clean the socket or replace the device with

another.

Record checksum/length error!

Usually this error indicates that a wrong file format has been

selected. It could also indicate that the input file has a record that

has been corrupted.

Selected the correct file format, or obtain a new copy of the input

file.

Tektronic hex file can be 64KB maximum!

This error is displayed when you want to save the buffer to a file,

and the buffer is bigger than 64KB.

The buffer can still be saved to disk, but only the first 64KB will be

saved. The rest will be lost.

Choose another file format if you need to save the whole buffer.

The pin number of test vectors in the buffer unmatched!

This message indicates that the test vectors in the buffer indicate a

different number of pins than actually found on the device.

This is caused when the wrong device is selected as the active

device, or the wrong file with test vectors is loaded into memory.

This error is also caused when an adapter is required for devices

with more than 48-pins. The test vectors try to drive the pins

directly, and this causes an error. Make sure that the file and device

correspond, and do not use test vectors on devices that need