Poor contact at pin %s!
The DATAMAN-48XP does an insertion test before
programming/erasing etc. any device.
This message indicates that the socket may be dirty; the device may
have been damaged etc. Clean the socket or replace the device with
another.
Record checksum/length error!
Usually this error indicates that a wrong file format has been
selected. It could also indicate that the input file has a record that
has been corrupted.
Selected the correct file format, or obtain a new copy of the input
file.
Tektronic hex file can be 64KB maximum!
This error is displayed when you want to save the buffer to a file,
and the buffer is bigger than 64KB.
The buffer can still be saved to disk, but only the first 64KB will be
saved. The rest will be lost.
Choose another file format if you need to save the whole buffer.
The pin number of test vectors in the buffer unmatched!
This message indicates that the test vectors in the buffer indicate a
different number of pins than actually found on the device.
This is caused when the wrong device is selected as the active
device, or the wrong file with test vectors is loaded into memory.
This error is also caused when an adapter is required for devices
with more than 48-pins. The test vectors try to drive the pins
directly, and this causes an error. Make sure that the file and device
correspond, and do not use test vectors on devices that need