beautypg.com

Dataman 48XP User Manual

Page 45

background image

45

Statistic

Menu Options

/

Statistics

Hot

key

F6

Action

Enables either the counter or alarm when the target count or

maximum failure count reaches the preset limit.

Active

Specifies the action you want to count in the statistics function.

Mass production enable:

Counts the mass production quantity (chips) into the

statistic display.

Program enable:

Counts the program activities into the statistic display.

Verify enable:

Counts the number of verify operations into the display.

Blank check enable:

Counts the blank check activities into the statistic display