have selected an incorrect device as active device, or the device is

an older/newer version than the device supported by the

DATAMAN-48XP.

Select the correct device as active device. If the error still occurs,

download the latest release of the software from our website. If you

are sure that the device you are using uses the same programming

algorithm as a device that is supported, you can use that device as

the active device. You can then disable device code checking by

setting the Operating Options.

No device on socket!

The DATAMAN-48XP has not detected a device in the socket.

The inserted device may be damaged. Replace it with a similar

device and try again.

No test version in the buffer!

The memory buffer does not contain any test vectors. When the

DATAMAN-48XP tries to verify/function test a PLD, it displays

this message.

Download a file that contains test vectors before doing a function

test. Test vectors are usually included in JEDEC files.

Not enough memory available to complete operation!

There isn’t enough memory available to complete the requested

operation. Free some memory and retry the operation.

Over current detected!

A current higher than expected was found. This might indicate that

the device has been damaged or is in short-circuit.

Check the socket or replace the device.