Altera MAX 10 Embedded Multipliers User Manual
Page 22

GUI Parameter
Parameter
Condition
Value
Description
Input Register > What
is the source for clock
input?
ACCUM_
SLOAD_REG
• Accumulator
> Create an
‘accum_sload’
input port =
On
• Accumulator
> More
Options
Clock0–Clock3
Specifies the clock
signal for the
accum_
sload
port.
Input Register > What
is the source for
asynchronous clear
input?
ACCUM_
SLOAD_ACLR
• Accumulator
> Create an
‘
accum_
sload
’ input
port = On
• Accumulator
> More
Options
• Aclr0–Aclr2
• None
Specifies the asynchro‐
nous clear source for
the first register on the
accum_sload
input.
Pipeline Register >
What is the source for
clock input?
ACCUM_
SLOAD_
PIPELINE_REG
• •
Accumulator
> Create an
‘
accum_
sload
’ input
port = On
• Accumulator
> More
Options
Clock0–Clock3
Specifies the source for
clock input.
Pipeline Register >
What is the source for
asynchronous clear
input?
ACCUM_
SLOAD_
PIPELINE_
ACLR
• Accumulator
> Create an
‘
accum_soad
’
input port =
On
• Accumulator
> More
Options
• Aclr0–Aclr2
• None
Specifies the source for
asynchronous clear
input.
Create an ‘
overflow
’
output port
—
—
On or Off
Overflow
port for the
accumulator
Add [] extra latency to
the multiplier output
EXTRA_
MULTIPLIER_
LATENCY
—
0, 1, 2, 3, 4, 5, 6,
7, 8, or 12
Specifies the number of
clock cycles of latency
for the multiplier
portion of the DSP
block. If the
MULTIPLIER_REG
parameter is specified,
then the specified clock
port is used to add the
latency.
UG-M10DSP
2014.09.22
ALTMULT_ACCUM Parameter Settings
5-7
ALTMULT_ACCUM (Multiply-Accumulate) IP Core References
Altera Corporation