There are three groups of options: General, General2, and Pipeling.
Table 4-1: LPM_MULT Parameters - General
This table lists the IP core parameters applicable to MAX 10 devices.
GUI Parameter
Parameter
Condition
Value
Description
Multiplier configuration
—
—
• Multiply
‘
dataa
’ input
by ‘datab’
input
• Multiply
‘
dataa
’ input
by itself
(squaring
operation)
Specifies the multiplier
configuration.
How wide should the
‘
dataa
’ input be?
LPM_
WIDTHA
—
1–256
Specifies the width of the
dataa[]
port.
How wide should the
‘
datab
’ input be?
LPM_
WIDTHB
—
1–256
Specifies the width of the
datab[]
port.
How should the width of
the ‘
result
’ output be
determined?
LPM_
WIDTHP
—
• Automatically
calculate the
width
• Restrict the
width to [] bits
Specifies how the result
width is determined.
How should the width of
the ‘
result
’ output be
determined? >
Restrict the width to []
bits
LPM_
WIDTHP
How should the
width of the
‘
result
’ output
be determined? >
Restrict the width
to [] bits = On
1–256
You can set the result
width.
©
2014 Altera Corporation. All rights reserved. ALTERA, ARRIA, CYCLONE, ENPIRION, MAX, MEGACORE, NIOS, QUARTUS and STRATIX words and logos are
trademarks of Altera Corporation and registered in the U.S. Patent and Trademark Office and in other countries. All other words and logos identified as
trademarks or service marks are the property of their respective holders as described at
www.altera.com/common/legal.html
. Altera warrants performance
of its semiconductor products to current specifications in accordance with Altera's standard warranty, but reserves the right to make changes to any
products and services at any time without notice. Altera assumes no responsibility or liability arising out of the application or use of any information,
product, or service described herein except as expressly agreed to in writing by Altera. Altera customers are advised to obtain the latest version of device
specifications before relying on any published information and before placing orders for products or services.
www.altera.com
101 Innovation Drive, San Jose, CA 95134