5 multiple evaluation, 2 configuration, 1 operating modes and parameters – Pilz PSSu K F INC User Manual
Page 19: Multiple evaluation, Configuration, Operating modes and parameters

Function description
Operating Manual PSSu K F INC
1001688EN06
19
Key to timing diagram:
Section
Function
Procedure for PSSu in system environ
ment B
a
Enter counter status
In the user program, assign the default
counter status to OutputData.NewCounter
Value
b
Transfer counter status
In the user program, set Out
putData.SetCounter
c
Acknowledge transfer
The module sets InputData.SetCounter
Done; InputData.Underflow and In
putData.Overflow are reset
D
Finish transfer
In the user program, reset Out
putData.SetCounter
e
Ready for new function
The module resets InputData.SetCounter
Done
4.1.5.5
Multiple evaluation
The module can evaluate the counter pulses once, twice or four times. Multiple evaluation
increases the number of measuring steps and reduces the output frequency of the incre
mental encoder.
Multiple evaluation is only possible in incremental encoder operating mode.
}
Single evaluation option:
Each rising edge at channel A increases the counter status.
}
Double evaluation option:
Each rising and each falling edge at channel A increases the counter status.
}
Quadruple evaluation option:
Each rising and each falling edge at channel A and channel B increases the counter
status.
The Double evaluation and Quadruple evaluation options may not be used for failsafe
applications.
4.2
Configuration
4.2.1
Operating modes and parameters
The module has the following configuration options:
Configuration
Default
value
Meaning
Operating mode
X
Incremental encoder mode
Counter mode
Period length measure
ment or latch function
X
Latch function
Period length measurement