Function description

Operating Manual PSSu K F INC
1001688­EN­06

19

Key to timing diagram:

Section

Function

Procedure for PSSu in system environ­
ment B

a

Enter counter status

In the user program, assign the default
counter status to OutputData.NewCounter­
Value

b

Transfer counter status

In the user program, set Out­
putData.SetCounter

c

Acknowledge transfer

The module sets InputData.SetCounter­
Done; InputData.Underflow and In­
putData.Overflow are reset

D

Finish transfer

In the user program, reset Out­
putData.SetCounter

e

Ready for new function

The module resets InputData.SetCounter­
Done

4.1.5.5

Multiple evaluation

The module can evaluate the counter pulses once, twice or four times. Multiple evaluation
increases the number of measuring steps and reduces the output frequency of the incre­
mental encoder.

Multiple evaluation is only possible in incremental encoder operating mode.

}

Single evaluation option:

Each rising edge at channel A increases the counter status.

}

Double evaluation option:

Each rising and each falling edge at channel A increases the counter status.

}

Quadruple evaluation option:

Each rising and each falling edge at channel A and channel B increases the counter
status.

The Double evaluation and Quadruple evaluation options may not be used for failsafe
applications.

4.2

Configuration

4.2.1

Operating modes and parameters

The module has the following configuration options:

Configuration

Default
value

Meaning

Operating mode

X

Incremental encoder mode

Counter mode

Period length measure­
ment or latch function

X

Latch function

Period length measurement