Wiring
Operating Manual PSSu E F ABS SSI(T)
1001455EN06
23
}
On base modules with screw terminals:
–
If you use a multistrand cable to connect the I/Os, it is recommended that you use
ferrules conforming to Parts 1 and 2 of DIN 46228, 0.14 ... 1.5 mm
2
, Form A or C,
although this is not essential. To crimp the ferrules you can use crimp pliers (crimp
form A or C) conforming to EN 609471, such as the PZ 1.5 or PZ 6.5 from
Weidmüller, for example.
–
Maximum torque setting: 0.8 Nm
}
Use copper wiring.
6.2
Terminal configuration
Base module
Terminal configuration
Screw terminals:
PSSu BP 1/8S
PSSu BP 1/8ST
Cage clamp terminals:
PSSu BP 1/8C
PSSu BP 1/8CT
Without Crail:
11: Input D+
(Data +)
21: Output Cl+
(Clock +)
1222: 0 V counter
(1222 linked within the base
module)
1323: Cable shield
(1323 linked within the base
module)
14: Input D
(Data )
24: Output Cl
(Clock )
21
11
22
12
23
13
24
14