Safety

Operating Manual PSSu E F ABS SSI(­T)
1001455­EN­06

11

}

If more than two counters are used, each individual counter module of a PSSu system
must supply diverse input values to the other counter modules of the PSSu system.

}

Safe standstill monitoring must be carried out by feasibility with a safe travel command
in the function block.

}

Test the safety functions when commissioning or recommissioning.

Intended use includes making the electrical installation EMC­compliant. Please refer to the
guidelines stated in the "PSSuniversal Installation Manual". The module is designed for use
in an industrial environment. It is not suitable for use in a domestic environment, as this can
lead to interference.

The following is deemed improper use in particular:

}

Any component, technical or electrical modification to the module

}

Use of the module outside the areas described in this manual

}

Any use of the module that is not in accordance with the technical details.

INFORMATION

The module is supported by PAS4000 from Version 1.1.1. We recommend
that you always use the latest version (download from www.pilz.de).

The PSSu E F ABS SSI module may be used in conjunction with the following base mod­
ules:

}

PSSu BP 1/8S

}

PSSu BP 1/8C

}

PSSu BP­C 1/8S

}

PSSu BP­C 1/8C

}

PSSu BP 1/12S

}

PSSu BP 1/12C

}

PSSu BP­C1 1/12S

}

PSSu BP­C1 1/12C

The module PSSu E F ABS SSI­T may be used in conjunction with the following base mod­
ules:

}

PSSu BP 1/8S­T

}

PSSu BP 1/8C­T

}

PSSu BP­C 1/8S­T

}

PSSu BP­C 1/8C­T

}

PSSu BP 1/12S­T

}

PSSu BP 1/12C­T

}

PSSu BP­C1 1/12S­T

}

PSSu BP­C1 1/12C­T

This manual is related to the following products: