Overview, Unit structure, 1 range – Pilz PNOZ ms1p standstill / speed monitor User Manual
Page 9: 2 unit features, 2overview, 1 unit structure
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
2-1
2.1
Unit structure
2
Overview
2
2000
Overview
Overview
2-
2.1
Unit structure
2100
Unit structure
2-
2.1.1
Range
2-
Scope of supply:
`
PNOZ ms1p expansion module
`
Jumper: 774 639
2.1.2
Unit features
2-
The product has the following features:
`
Monitoring of 2 independent axes
`
Connection per axis
– 1 incremental encoder
or
– 2 proximity switches
or
– 1 incremental encoder and 1 proximity switch
`
Measured variables:
– Standstill
– Speed (8 values can be set)
– Direction of rotation
`
Axis types, input device types and reset mode can be selected in the
PNOZmulti Configurator
`
Status indicators for
– Supply voltage
– Incremental encoders
– Proximity switches
– Axis status, standstill and excess speed
– Faults on the system
`
Proximity switch connection technology: Plug-in connection terminals
(either cage clamp terminal or screw terminal)
`
Incremental encoder connection technology:
RJ-45 female connector
`
Galvanic isolation between the connections X1, X12 and X22
`
Max. 4 speed monitors can be connected to the base unit