beautypg.com

Function description, Device properties, 1 integrated protection mechanisms – Pilz PNOZ ms1p standstill / speed monitor User Manual

Page 17: 2 function description, 1 operation, 2 block diagram, 4function description, 1 device properties

background image

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

4-1

4.1

Device properties

4

Function description

4

4000

Function description

Function description

4-

4.1

Device properties

4100

Device properties

4-

4.1.1

Integrated protection mechanisms

Integrated protection mechanisms

4-

The relay conforms to the following safety criteria:

`

The circuit is redundant with built-in self-monitoring.

`

The safety function remains effective in the case of a component

failure.

4.1.2

Function description

Function description

4-

4.1.2.1

Operation

Operation

4-

The speed monitor can independently monitor two axes for standstill,

speed and direction of rotation. The speed monitor signals the status of

the monitored values to the base unit. Depending on the safety circuit

loaded, the values can be transferred from the base unit, e.g. to a relay

output on the safety system. Incremental encoders and/or proximity de-

tectors can be used to record the values.

The configuration of the speed monitor is described in detail in the

PNOZmulti Configurator's online help.

4.1.2.2

Block diagram

Block diagram

4-

I10 I11

Interface to pr

evious

module

Interface to next module

I20 I21 24 V 24 V 24 V

X12

X22

Axis 1

Axis 2

24 V

0 V

0 V 0 V 0 V

X1

This manual is related to the following products: