Function description, Device properties, 1 integrated protection mechanisms – Pilz PNOZ ms1p standstill / speed monitor User Manual
Page 17: 2 function description, 1 operation, 2 block diagram, 4function description, 1 device properties
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
4-1
4.1
Device properties
4
Function description
4
4000
Function description
Function description
4-
4.1
Device properties
4100
Device properties
4-
4.1.1
Integrated protection mechanisms
Integrated protection mechanisms
4-
The relay conforms to the following safety criteria:
`
The circuit is redundant with built-in self-monitoring.
`
The safety function remains effective in the case of a component
failure.
4.1.2
Function description
Function description
4-
4.1.2.1
Operation
Operation
4-
The speed monitor can independently monitor two axes for standstill,
speed and direction of rotation. The speed monitor signals the status of
the monitored values to the base unit. Depending on the safety circuit
loaded, the values can be transferred from the base unit, e.g. to a relay
output on the safety system. Incremental encoders and/or proximity de-
tectors can be used to record the values.
The configuration of the speed monitor is described in detail in the
PNOZmulti Configurator's online help.
4.1.2.2
Block diagram
Block diagram
4-
I10 I11
Interface to pr
evious
module
Interface to next module
I20 I21 24 V 24 V 24 V
X12
X22
Axis 1
Axis 2
24 V
0 V
0 V 0 V 0 V
X1