beautypg.com

2 connection of 4 proximity switches, 6commissioning, 2 preparing for operation – Pilz PNOZ ms1p standstill / speed monitor User Manual

Page 32

background image

6.2

Preparing for operation

6

Commissioning

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

6-8

6.2.4.2

Connection of 4 proximity switches

Connection of 4 proximity switches

6-

Description

`

4 proximity switches, pnp-switching

`

Connection through 24 V terminals and 0 V

Fig. 6-9:

Connection of 4 proximity switches, pnp-switching, con-

nection through 24 V terminals and 0 V

I10

I11

I20

I21

24V

24V

24V

0V

0V

0V

X22

X12

+

-

Incremental encoder

Drive

...

PNOZ msi1p ... msi4p ...

24 V DC

0 V

Speed monitor

pnp

This manual is related to the following products: