6commissioning, 2 preparing for operation – Pilz PNOZ ms1p standstill / speed monitor User Manual
Page 29
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
6-5
6.2
Preparing for operation
6
Commissioning
6.2.3
Connection of proximity switches and incremental encoder
Connection of proximity switches and incremental encoder
6-
6.2.3.1
Proximity switch and incremental encoder on various axes
Proximity switch and incremental encoder on various axes
6-
Axis 1:
proximity switch on I10, I11
or
incremental encoder on X12
Axle 2:
proximity switch on I10, I21
or
incremental encoder on X22
Fig. 6-6:
Proximity switch and incremental encoder on various axes
I20
I11
I21
I10
0 V
L+
L-
X12
X22
Axis 2