StorCase Technology InfoStation 12-Bay 4U Ultra160/SATA User Manual
Page 52
![background image](/manuals/742413/52/background.png)
InfoStation 12-bay RAID User's Guide - Rev. C00
StorCase Technology, Inc.
RAID Controller Configuration
41
6.8 Expand Array
CAUTION:
Data may be lost during the expansion process! StorCase strongly recommends
the user to backup all data before expanding.
NOTE:
Make sure that new disk capacity is equal to or larger than the current online
capacity.
Select array to be expanded (Array 1-4), then the number of disks in the new array.
To expand disk capacity:
1.
Connect new disk.
2.
Use Expand Array menu to select the number of disks in the array.
3.
Go to the 1.1.4 Slice menu. The new capacity should appear as a new slice. If no
slices were created previously, the new capacity will appear as Slice 1.
6.9 Update ROM
CAUTION:
Data may be lost during the expansion process! StorCase strongly recommends
the user to backup all data before expanding.
NOTE:
Configuration changes made in the RAID Functions menu must be saved before
changes can take effect. Refer to section "5 NVRAM" for further information.
This function enables the user to update the RAID controller's firmware.