2 fibre params – StorCase Technology InfoStation 12-Bay 4U Ultra160/SATA User Manual
Page 37
![background image](/manuals/742413/37/background.png)
26
RAID Controller Configuration
StorCase Technology, Inc.
InfoStation 12-bay RAID User's Guide - Rev. C00
2 Fibre Params
(For FC-to-SATA version only)
NOTE:
Configuration changes made in the Fibre Params menu must be saved and the
RAID controller restarted before changes can take effect. Refer to section "5
NVRAM" for further information.
2 Fibre Params
2.1 Primary FC
2.1.1
Enable Hard
Loop ID
2.1.2
Set Hard
Loop ID
2.1.3
Set Connection
Mode
2.1.4
Set Data Rate
2.2 Secondary
FC*
2.1.5
LUN Map
* Submenus are the same
as 2.1 Primary FC
2.3 SAN Mask
1Gbit / 2Gbit /
Auto-Negotiated
Match slices in
existing arrays
(up to 16 LUNs)
Arbitration Loop /
Point-to-Point
2.3.1
Visible For
All Hosts
** Submenus are the same
as 2.3.2.1 Port 1
2.3.2
SAN Mapping
Enable / Disable
Enable / Disable
Enable / Disable
2.3.1.1 Port 1
2.3.1.2 Port 2
2.3.2.1 Port 1
2.3.2.2 Port 2**
2.3.2.1.1 - 2.3.2.1.8
Select Host
Select LUN
2.3.3.1 - 2.3.3.8
Select Host
2.3.3
Edit WWN
Table
2.3.4
View WWN
Table
2.3.5
View SAN
Mapping
2.3.5.1 Port 1
2.3.5.2 Port 2
Yes / No
2.1 Primary FC
This function enables the user to configure Primary FC settings.
2.1.1 Enable Hard Loop ID
Select either Enable or Disable (default). Enable allows the user to set the ID manually. Disable
allows the controller to set the ID.
2.1.2 Set Hard Loop ID
Enter the Hard Loop ID for this controller (Hard Loop ID must be enabled).