beautypg.com

StorCase Technology InfoStation 12-Bay 4U Ultra160/SATA User Manual

Page 51

background image

40

RAID Controller Configuration

StorCase Technology, Inc.

InfoStation 12-bay RAID User's Guide - Rev. C00

6.3 Beeper

Select either Clear, Enable (default), or Disable. Clear is used to stop a sounding beeper.

6.4 Stop Modem

Select either No (default) or Yes. Select Yes to halt the transmission of subsequent alert

pager/Fax messages once the message has been received and acknowledged.

6.5 Add Disk

NOTE:

Add disk(s) to an existing configuration while the RAID controller is online.

Select disk number (1-12).

6.6 Remove Disk

NOTE:

Remove disk(s) from an existing configuration while the RAID controller is on-

line.

Select disk number (1-12). This function enables the user to shutdown a potentially faulty disk.

If a spare disk is available, it will automatically be added (default = None).

6.7 Statistic

NOTE:

This option cannot be viewed from the Control Panel (it can only be viewed from

the Monitor Utility).

This function enables the user to display system data. Data includes:

• Current settings saved in NVRAM

• Statistical analysis of read and write operations, plus the percentage of cache hits