2 scsi params – StorCase Technology InfoStation 12-Bay 4U Ultra160/SATA User Manual
Page 35
![background image](/manuals/742413/35/background.png)
24
RAID Controller Configuration
StorCase Technology, Inc.
InfoStation 12-bay RAID User's Guide - Rev. C00
2 SCSI Params
(For SCSI-to-SATA version only)
NOTE:
Configuration changes made in the SCSI Params menu must be saved and the
RAID controller restarted before changes can take effect. Refer to section "5
NVRAM" for further information.
2 SCSI Params
2.1 Primary SCSI
2.1.1 Set SCSI ID
2.1.2 Termination
2.1.3 Tag
Queuing
2.1.4 Speed
2.2 Secondary
SCSI*
2.1.5 Wide
* Submenus are the same
as 2.1 Primary SCSI
2.1.6 LUN Map
0-14 / Multiple
Enable / Disable
Ultra3 / Ultra2 /
Ultra / Fast
Enable / Disable
Match slices in
existing arrays
(up to 16 LUNs)
Enable / Disable
2.1 Primary SCSI
This function enables the user to configure Primary SCSI settings.
2.1.1 Set SCSI ID
Select either 0-14 or Multiple (default =0). ID7 is reserved for the SCSI card.
2.1.2 Termination
NOTE:
If the InfoStation is the only SCSI device on the bus or is at the end of a daisy-
chain, termination should be Enabled. If the InfoStation is in the middle of a daisy-
chain, termination should be Disabled.
Select either Enable (default) or Disable. Disable termination if terminators have been
installed on each SCSI bus.
2.1.3 Tag Queuing
Select either Enable (default) or Disable. Tag Queuing improves the performance of the
RAID controller when processing multiple requests from the host.