beautypg.com

2 scsi params – StorCase Technology InfoStation 12-Bay 4U Ultra160/SATA User Manual

Page 35

background image

24

RAID Controller Configuration

StorCase Technology, Inc.

InfoStation 12-bay RAID User's Guide - Rev. C00

2 SCSI Params

(For SCSI-to-SATA version only)

NOTE:

Configuration changes made in the SCSI Params menu must be saved and the

RAID controller restarted before changes can take effect. Refer to section "5

NVRAM" for further information.

2 SCSI Params

2.1 Primary SCSI

2.1.1 Set SCSI ID

2.1.2 Termination

2.1.3 Tag

Queuing

2.1.4 Speed

2.2 Secondary

SCSI*

2.1.5 Wide

* Submenus are the same

as 2.1 Primary SCSI

2.1.6 LUN Map

0-14 / Multiple

Enable / Disable

Ultra3 / Ultra2 /

Ultra / Fast

Enable / Disable

Match slices in

existing arrays

(up to 16 LUNs)

Enable / Disable

2.1 Primary SCSI

This function enables the user to configure Primary SCSI settings.

2.1.1 Set SCSI ID

Select either 0-14 or Multiple (default =0). ID7 is reserved for the SCSI card.

2.1.2 Termination

NOTE:

If the InfoStation is the only SCSI device on the bus or is at the end of a daisy-

chain, termination should be Enabled. If the InfoStation is in the middle of a daisy-

chain, termination should be Disabled.

Select either Enable (default) or Disable. Disable termination if terminators have been

installed on each SCSI bus.

2.1.3 Tag Queuing

Select either Enable (default) or Disable. Tag Queuing improves the performance of the

RAID controller when processing multiple requests from the host.