beautypg.com

Ntellisys, Daptive, Ressure – Nor-Cal Intellisys Adaptive Pressure Controllers User Manual

Page 9: Ontrollers

background image

Call toll free

800-824-4166

or 530-842-4457

FAX 530-842-9130

9

I

ntellIsys

A

dAptIve

p

ressure

C

ontrollers

APC-OP-LIT 1/12

3.3 - DC Powered Controllers with Serial I/O Interface

Refer to the following diagram and tables when connecting to a DC powered APC controller including model APC-800L-A-S01.

TAbLE 3.3.3 -

(J4) “APC-800L-A-S01” VALVE

CONNECTOR, Db-15 PLUG

PIn

SIGnAl

ASSIGnment

1

Drive A+

2

Drive A-

3

Drive B-

4

Drive B+

5

Sense B-

6

Sense B+

7

Sense A-

8

Sense A+

9

Reserved

10

Reserved

11

Reserved

12

Reserved

13

Reserved

14

Reserved

15

Reserved

TAbLE 3.3.4 -

(J3) “APC-800L-A-S01” I/O

CONNECTOR,

Db-15 RECEPTACLE

PIn FunctIon

1

Chassis GND

2

RS-232 TX (data from

APC to host), or 485A

3

RS-232 RX (data from

host to APC), or 485B

4

N/C

5

N/C

6

N/C

7

Digital GND

8

N/C

9

N/C

10

N/C

11

N/C

12

Valve Closed input

13

Digital GND

14

\Valve Closed Output\

15

TTL Output Common

TAbLE 3.3.2 -

(J2) “APC-800L-A-S01” POWER

CONNECTOR, Db-9 PLUG

PIn

FunctIon

1

Chassis GND

2

Power RTN

3

Power RTN

4

Power +24V IN

5

Power +24V IN

6

N/C

7

N/C

8

N/C

9

N/C

TAbLE 3.3.1 - (J1)

“APC-800L-A-S01”

GAUGE CONNECTOR,

Db-15 RECEPTACLE

PIn

FunctIon

1

Chassis GND

2

Chassis GND

3

N/C

4

Signal common from gauge 2

5

Signal input from gauge 2

6

N/C

7

Signal common from gauge 1

8

Signal input from gauge 1

9

+15V supply to gauge

10

+15V supply to gauge

11

Power Supply Common

12

Power Supply Common

13

N/C

14

-15V supply to gauge

15

-15V supply to gauge

2.49

5.12

5.95

4.15

Status

LED

Status LEDs

POWER

I/O