I

ntellIsys

A

dAptIve

p

ressure

C

ontrollers

APC-OP-LIT 1/12

TAbLE 3.7.1 –

(J1) “IqD” DEVICENET

NETWORk CONNECTOR

PIn

FunctIon

1

Drain

2

Power In +

3

Power In -

4

CAN H

5

CAN L

1

4

3

2

5

AUXILIARY

GAUGE

TM

Valve Open/Close

membrane switches

Indicating LEDs

3.7 - DC Powered IqD Controlled Valve with Serial and DeviceNet I/O Interface

Refer to the following diagram and tables when connecting to an IQD controller including models TbV-IqD, TSS-IqD and TPV-IqD.

TAbLE 3.7.3 – (J3) “IqD”

GAUGE CONNECTOR,

Db-9 RECEPTACLE

PIn #

FunctIon

1

Signal input from gauge 1

2

+15 V supply to gauge

3

-15 V supply to gauge

4

Not used

5

Signal input from gauge 2

6

Signal common from gauge 2

7

Not used

8

Signal common from gauge 1

9

Power supply common

TAbLE 3.7.2 – (J2) “IqD”

AUXILIARy CONNECTOR,

Db-15 RECEPTACLE

PIn

FunctIon

1

Not used

2

RS-232 TX (data from IQ to

host)/485 (A)

3

RS-232 RX (data from host to

IQ)/485 (B)

4

Digital GND

5

Power RTN

6

Not used

7

Power +24V in

8

Not used

9

Analog CDG1 Out

10

Analog Valve Out

11

Analog GND

12

TTL Out Common

13

\Valve Open Out\

14

\Valve Closed Out\

15

Chassis GND