APC-OP-LIT 1/12

2.51

5.74

5.69

4.78

Indicating LEDs

3.5 - DC Powered Controllers with Serial and DeviceNet I/O Interface

Refer to the following diagrams and tables when connecting to an D/C powered APC controller including models APC-100L-D, APC-200L-D, APC-300L-D, APC-700L-D and

APC-800L-D.

TAbLE 3.5.1 –

(J1) “APC-X00L-D”

DEVICENET NETWORk

CONNECTOR

PIn

FunctIon

1

Drain

2

Power In +

3

Power In -

4

CAN H

5

CAN L

1

4

3

2

5

TAbLE 3.5.2 – (J2) “APC-X00L-D”

AUXILIARy CONNECTOR,

Db-15 RECEPTACLE

PIn

FunctIon

1

Not used

2

RS-232 TX (data from IQ to

host)/485 (A)

3

RS-232 RX (data from host to

IQ)/485 (B)

4

Digital GND

5

Power RTN

6

Not used

7

Power +24V in

8

Not used

9

Analog CDG Out

10

Analog Valve Out

11

Analog GND

12

TTL Out Common

13

\Valve Open Out\

14

\Valve Closed Out\

15

Chassis GND

TAbLE 3.5.3 – (J3) “APC-X00L-D”

GAUGE CONNECTOR,

Db-9 RECEPTACLE

PIn #

FunctIon

1

Signal input from gauge 1

2

+15 V supply to gauge

3

-15 V supply to gauge

4

Not used

5

Signal input from gauge 2

6

Signal common from gauge 2

7

Not used

8

Signal common from gauge 1

9

Power supply common

TAbLE 3.5.4 - (J4) “APC-X00L-D”

VALVE CONNECTOR,

Db-15 RECEPTACLE

PIn

SIGnAl

ASSIGnment

1

Drive A+

2

Drive A-

3

Drive B-

4

Drive B+

5

Sense B-

6

Sense B+

7

Sense A-

8

Sense A+

9

Reserved

10

Reserved

11

Reserved

12

Reserved

13

Reserved

14

Reserved

15

Reserved