Ntellisys, Daptive, Ressure – Nor-Cal Intellisys Adaptive Pressure Controllers User Manual
Page 7: Ontrollers, 1 - a/c powered touch-panel controller interface, Intelli sys
Call toll free
800-824-4166
or 530-842-4457
•
FAX 530-842-9130
7
I
ntellIsys
A
dAptIve
p
ressure
C
ontrollers
APC-OP-LIT 1/12
VALVE
VALVE
TTL/ANALOG I/O
TTL/ANALOG I/O
GAUGE 1
GAUGE 1
SW1
SW1
POWER
!
100-240V~
50-60 Hz
POWER
!!
100-240V~
50-60 Hz
SERIAL
SERIAL
GAUGE 2
GAUGE 2
POWER
ON
OFF
I
O
POWER
ON
OFF
I
O
8.00
3.50
3.1 - A/C Powered Touch-Panel Controller Interface
Refer to the following diagrams and tables when connecting to an A/C powered APC Touch Panel Controller including models APC-150-A, APC-250-A, APC-350-A, APC-
750-A and APC-850-A.
TAbLE 3.1.6 -
(J6) “APC-X50-A”ANALOG / TTL
CONNECTOR, Db-37 RECEPTACLE
PIn
FunctIon
1
N/C
2
N/C
3
N/C
4
Digital GND / RS232 Common
5
\CDG2 Select In\
6
\Position Control Select In\
7
N/C
8
\Close Valve In\
9
\Control Active Out\
10
\Analog Div 10 Select In\
11
\Analog SP Control Select In\
12
Digital GND / RS232 Common
13
TTL Out Common
14
N/C
15
N/C
16
N/C
17
N/C
18
Analog Valve Out (0-5 VDC)
19
\Valve Open Out\
20
N/C
21
N/C
22
N/C
23
\Valve Closed Out\
24
Fault Out
25
\Zero Gauge Select In\
26
See NOTE below
27
\Open Valve In\
28
PLO #2 Status
29
PLO #1 Status
30
N/C
31
N/C
32
N/C
33
Analog SP+ In
34
Analog SP- In
35
Analog GND
36
Analog CDG Out
37
Analog Valve Out
NOTE:
For 150-, 250- &
350- series controllers,
pin 26 is defined as
\Hold Valve Select In\
NOTE:
For 750- &
850- series controllers,
pin 26 is defined as
\Valve Initialization
Enable In\
TAbLES 3.1.5 - (SW1) “APC-X50-A” DIP SWITCh
SETTINGS FOR SERIAL COmmUNICATIONS
BAuD rAte
SwItch 1
SwItch 2
19200
OFF (up)
OFF (up)
9600
ON (down)
OFF (up)
4800
OFF (up)
ON (down)
1200
ON (down)
ON (down)
PArIty
SwItch 3
SwItch 4
None
OFF (up)
Either ON or OFF
Odd
ON (down)
OFF (up)
Even
ON (down)
ON (down)
StoP BItS*
SwItch 5
1
OFF (up)
2
ON (down)
* If parity is enabled (either odd or even) then only 1 stop bit is used
and SW1 position 5 will be ignored
other
FunctIonS
SwItch
6
SwItch
7
SwItch
8
ON (down)
Enable
RS-485
Analog S.P.
0-5 VDC
Reserved
OFF (up)
RS-232
Analog S.P.
0-10 VDC
Reserved
TAbLE 3.1.4 - (J2) “APC-X50-
A” RS-232 SERIAL PORT, Db-9
RECEPTACLE
PIn
SIGnAl
ASSIGnment
1
RS485 (B)
2
RS-232 TX (data from
APC to host)
3
RS-232 RX (data from
host to APC)
4
N/C
5
Signal Common
6
N/C
7
N/C
8
N/C
9
RS485 (A)
TAbLE 3.1.3 - (J5)
“APC-X50-A” VALVE
CONNECTOR,
Db-15 RECEPTACLE
PIn SIGnAl
ASSIGnment
1
Drive A+
2
Drive A-
3
Drive B-
4
Drive B+
5
Sense B-
6
Sense B+
7
Sense A-
8
Sense A+
9
Reserved
10
Reserved
11
Reserved
12
Reserved
13
Reserved
14
Reserved
15
Reserved
NOTE:
Function \names\ with a
backward slash indicate active low
input or output signals
TAbLE 3.1.2- (J1) “APC-X50-A” A/C
POWER CONNECTOR
PIn
FunctIon
1
Neutral
2
Ground
3
Line in 100 to 240 VAC
1
3
2
TAbLE 3.1.1 - (J3 & J4)
“APC-X50-A” GAUGE
CONNECTOR Db-9 RECEPTACLE
(IDENTICAL PINOUTS)
PIn
SIGnAl
ASSIGnment
1
Signal input from gauge
2
N/C
3
N/C
4
+15VDC output to gauge
5
-15VDC output to gauge
6
N/C
7
N/C
8
Signal common from
gauge
9
Power common
output to gauge
Intelli
sys
TM
ADAPTIVE PRESSURE CONTROLLER
CLOSED
OPEN
CONTROL
FAULT
POWER
CLOSED
CLOSED
OPEN
OPEN
CONTROL
CONTROL
FAULT
FAULT
POWER
POWER
3.50
8.50
Power
On/Off
Switch