Page 7: Ontrollers, 1 - a/c powered touch-panel controller interface, Intelli sys

background image

Call toll free

800-824-4166

or 530-842-4457

FAX 530-842-9130

7

I

ntellIsys

A

dAptIve

p

ressure

C

ontrollers

APC-OP-LIT 1/12

VALVE

VALVE

TTL/ANALOG I/O

TTL/ANALOG I/O

GAUGE 1

GAUGE 1

SW1

SW1

POWER

!

100-240V~

50-60 Hz

POWER

!!

100-240V~

50-60 Hz

SERIAL

SERIAL

GAUGE 2

GAUGE 2

POWER

ON

OFF

I

O

POWER

ON

OFF

I

O

8.00

3.50

3.1 - A/C Powered Touch-Panel Controller Interface

Refer to the following diagrams and tables when connecting to an A/C powered APC Touch Panel Controller including models APC-150-A, APC-250-A, APC-350-A, APC-

750-A and APC-850-A.

TAbLE 3.1.6 -

(J6) “APC-X50-A”ANALOG / TTL

CONNECTOR, Db-37 RECEPTACLE

PIn

FunctIon

1

N/C

2

N/C

3

N/C

4

Digital GND / RS232 Common

5

\CDG2 Select In\

6

\Position Control Select In\

7

N/C

8

\Close Valve In\

9

\Control Active Out\

10

\Analog Div 10 Select In\

11

\Analog SP Control Select In\

12

Digital GND / RS232 Common

13

TTL Out Common

14

N/C

15

N/C

16

N/C

17

N/C

18

Analog Valve Out (0-5 VDC)

19

\Valve Open Out\

20

N/C

21

N/C

22

N/C

23

\Valve Closed Out\

24

Fault Out

25

\Zero Gauge Select In\

26

See NOTE below

27

\Open Valve In\

28

PLO #2 Status

29

PLO #1 Status

30

N/C

31

N/C

32

N/C

33

Analog SP+ In

34

Analog SP- In

35

Analog GND

36

Analog CDG Out

37

Analog Valve Out

NOTE:

For 150-, 250- &

350- series controllers,

pin 26 is defined as

\Hold Valve Select In\

NOTE:

For 750- &

850- series controllers,

pin 26 is defined as

\Valve Initialization

Enable In\

TAbLES 3.1.5 - (SW1) “APC-X50-A” DIP SWITCh

SETTINGS FOR SERIAL COmmUNICATIONS

BAuD rAte

SwItch 1

SwItch 2

19200

OFF (up)

OFF (up)

9600

ON (down)

OFF (up)

4800

OFF (up)

ON (down)

1200

ON (down)

ON (down)

PArIty

SwItch 3

SwItch 4

None

OFF (up)

Either ON or OFF

Odd

ON (down)

OFF (up)

Even

ON (down)

ON (down)

StoP BItS*

SwItch 5

1

OFF (up)

2

ON (down)

* If parity is enabled (either odd or even) then only 1 stop bit is used

and SW1 position 5 will be ignored

other

FunctIonS

SwItch

6

SwItch

7

SwItch

8

ON (down)

Enable

RS-485

Analog S.P.

0-5 VDC

Reserved

OFF (up)

RS-232

Analog S.P.

0-10 VDC

Reserved

TAbLE 3.1.4 - (J2) “APC-X50-

A” RS-232 SERIAL PORT, Db-9

RECEPTACLE

PIn

SIGnAl

ASSIGnment

1

RS485 (B)

2

RS-232 TX (data from

APC to host)

3

RS-232 RX (data from

host to APC)

4

N/C

5

Signal Common

6

N/C

7

N/C

8

N/C

9

RS485 (A)

TAbLE 3.1.3 - (J5)

“APC-X50-A” VALVE

CONNECTOR,

Db-15 RECEPTACLE

PIn SIGnAl

ASSIGnment

1

Drive A+

2

Drive A-

3

Drive B-

4

Drive B+

5

Sense B-

6

Sense B+

7

Sense A-

8

Sense A+

9

Reserved

10

Reserved

11

Reserved

12

Reserved

13

Reserved

14

Reserved

15

Reserved

NOTE:

Function \names\ with a

backward slash indicate active low
input or output signals

TAbLE 3.1.2- (J1) “APC-X50-A” A/C

POWER CONNECTOR

PIn

FunctIon

1

Neutral

2

Ground

3

Line in 100 to 240 VAC

1

3

2

TAbLE 3.1.1 - (J3 & J4)

“APC-X50-A” GAUGE

CONNECTOR Db-9 RECEPTACLE

(IDENTICAL PINOUTS)

PIn

SIGnAl

ASSIGnment

1

Signal input from gauge

2

N/C

3

N/C

4

+15VDC output to gauge

5

-15VDC output to gauge

6

N/C

7

N/C

8

Signal common from

gauge

9

Power common

output to gauge

Intelli

sys

TM

ADAPTIVE PRESSURE CONTROLLER

CLOSED

OPEN

CONTROL

FAULT

POWER

CLOSED

CLOSED

OPEN

OPEN

CONTROL

CONTROL

FAULT

FAULT

POWER

POWER

3.50

8.50

Power

On/Off

Switch