beautypg.com

Machine stroking mode settings – LINK Systems LinkNet II User Manual

Page 40

background image

Stroke: The stroke of the press.

Con. Rod Length: The length of the connecting rod that goes from the crankshaft to the slide.

Min. Shutheight: The minimum shutheight of which the press is capable.

Max. Shutheight: The maximum shutheight of which the press is capable.

Bed Width: The width of the press bed.

Bed Depth: The depth of the press bed.

Coil Feed Capable: Check this box if the press is equipped with a coil feed.

Max Coil Width: This setting is only available if “Coil Feed Capable” is checked. The maximum width
of material that the coil feed can handle.

Max. Coil Thickness: This setting is only available if “Coil Feed Capable” is checked. The maximum
thickness of material that the coil feed can handle.


4.9.1.3

Machine Stroking Mode Settings

The “Stroking Modes”

settings page (see Figure
4.22) contains inform
ation
about the available stroking
modes of the machine as well
as the minimum and
maximum stroking speeds.
The settings in this page are
not currently used by
LinkNet, but may be in the
future. At present, these are
for informational purposes.
The information and settings
on this page are:

Stroking Modes: If an
OmniLink 5000 press control
is on the press, the available
press stroking modes will be
reported here but cannot be
changed. Otherwise, check the modes that are available on the press being configured.

Figure 4.22: Machine Configuration Stroking Modes Dialog Box


Minimum SPM: The minimum strokes per minute that the machine is capable of running.

Maximum SPM: The maximum strokes per minute that the machine is capable of running.

Manual Version 1.1

10/28/2001

4.18