Figure 2.2, Regular drop box network connections, Figure 2.3 – LINK Systems LinkNet II User Manual
Page 13: Repeater drop box network connections

Figure 2.2: Regular Drop Box Network Connections
Figure 2.3: Repeater Drop Box Network Connections
All three connectors should be wired as follows:
GND
Green/White and White/Green
RXD+
Orange/White
RXD- White/Orange
TXD+
Blue/White
TXD- White/Blue
SHLD
Shield (bare) Wire of Cable
For Repeaters Only:
L1
“Hot” side of 110V AC
L2
“Neutral” side of 110V AC
M. GND Machine Ground
Some older versions of the drop box do not have the “SHLD” terminal. In this case, tie the shields of all
the cables together with a wire nut.
Whenever possible, the drop boxes should be mounted on the press in easy reach for troubleshooting
purposes. In addition, the length of the line from the drop box to the Link equipment should be kept as
short as reasonably possible. The drop boxes have knockouts sized for ½” conduit or cord grips.
Manual Version 1.1
10/28/2001
2.3