beautypg.com

Appendix, Input and router defaults, Amplifier and device defaults – Lab.gruppen PLM 20K44 User Manual

Page 69

background image

9. Appendix

PLM+ SERIES Operation Manual rev 1.0.0

69

9.3.2. Input and Router Defaults

Autoselect:

On

Input sensitivity:

+26 dBu

Dante:

Disabled

AES3:

Terminated

Iso-Float:

Enabled

Router 1:

Priority 1 = Dante Receiver (Ch.1)

Priority 2 = Dante Receiver (Ch.5)

Priority 3 = AES1 (Ch.1)

Priority 4 = Analog 1

Router 2:

Priority 1 = Dante Receiver (Ch.2)

Priority 2 = Dante Receiver (Ch.6)

Priority 3 = AES1 (Ch.2)

Priority 4 = Analog 2

Router 3:

Priority 1 = Dante Receiver (Ch.3)

Priority 2 = Dante Receiver (Ch.7)

Priority 3 = AES1 (Ch.3)

Priority 4 = Analog 3

Router 4:

Priority 1 = Dante Receiver (Ch.4)

Priority 2 = Dante Receiver (Ch.8)

Priority 3 = AES1 (Ch.4)

Priority 4 = Analog 4

9.3.3. Amplifier and Device Defaults

Attenuation:

0 dB

Polarity:

Positive (In phase)

Mutes:

Unmuted

Load Model:

No Load Model

Breaker Emulation Limiter: PLM 20K44 - 32A

PLM 12K44 - 25A

IP Configuration:

Auto Zero Conf. (Auto IP)

Dual Redundancy:

Disabled

Dante Slave Only:

Enabled