Step 9 – test mode – Datalogic Scanning Matrix 400 User Manual
Page 28
MATRIX 400™ REFERENCE MANUAL
18
1
STEP 9 – TEST MODE
Use a code suitable to your application to test the reading performance of the system.
1. Enter the Test function by pressing and holding the X-PRESS™ push button until the
Test LED is on.
2. Release the button to enter the Test function.
Once entered, the Bar Graph on the five LEDs is activated and if the reader starts
reading codes the Bar-Graph shows the Good Read Rate. In case of no read condition,
only the STATUS LED is on and blinks.
READY
green
green
yellow
yellow
red
SETUP
FOCUS
TEST
LEARN
GOOD
TRIGGER
COM
STATUS
Figure 17 – X-PRESS™ Interface: Test Function
3. To exit the Test, press the X-PRESS™ push button once.
NOTE
By default, the Test exits automatically after three minutes.
The Bar Graph has the following meaning:
READY
95%
75%
60%
40%
20%
SETUP
FOCUS
TEST
LEARN
GOOD
TRIGGER
COM
STATUS