Maintenance – Glow-worm Ultracom2 35 Store User Manual
Page 59

0020112185_PROTO_13 - 01/11 - Glow-worm
- 57 -
19.5.6
Re-assembling the burner group
• Place the burner assembly on the heat exchanger (21).
• Progressively tighten the 4 nuts (12) in an alternate order.
• Reassemble the silencer.
• Connect the gas pipe (36) with a new gasket to the burner
group.
• Connect the spark electrode connector (5) to the igniter unit.
• Connect the connector to the gas valve (37) and the fan (34).
• Open the appliance’s gas input.
• Check the tightness of the gas connection.
19.5.7
Heating flow Thermistor
• Remove the electrical connections from the thermistor (28).
• Remove the retaining clip from the flow pipe (27).
i
When reconnecting, the polarity of the wiring to
thermistors is not important.
19.5.8
Heating Return Thermistor
• Remove the electrical connections from the thermistor (26).
• Remove the retaining clip from the return pipe (24).
i
When reconnecting, the polarity of the wiring to
thermistors is not important.
19.5.9
Gas valve
• Remove the burner door (11) refering to chapter "Dismantling
the burner door".
• Remove the two gas valve retaining screws (30).
• Remove the gas valve (31) and the gasket (32).
• Fit the new gas valve and the new gasket by repeating the
operations in reverse.
• After assembly test for gas tightness and purge in accordance
with the current issue of BS6891or in IE, the current edition of
I.S.813 “Domestic Gas Installations”.
• Check the combustion CO
2
.
19.5.10 fan
• Remove the burner door (11) refering to chapter "Dismantling
the burner door".
• Remove the gas valve (31) (see previous paragraph).
• Loosen the 3 screws (38) located on the burner door (11).
• Remove the fan (33) and the gasket (35).
• Fit the new gasket (35).
• Screw the new fan to the burner door (11).
• After assembly test for gas tightness and purge in accordance
with the current issue of BS6891or in IE, the current edition of
I.S.813 “Domestic Gas Installations”.
19.6 Condensate trap
a
Warning: condensate is mildly acidic. Wear protective
gloves.
1
2
6
7
3
5
4
Key
1 Condensate reservoir
2 Condensate outlet pipe
3 Screws
4 Condensate trap
5 Condensate reservoir retaining clips
6 Hose
7 Heat exchanger
• Place a container under the condensate trap (4).
• Remove the condensate (1) from the reservoir.
• Disconnect the condensation discharge (2).
• Disconnect the hose (6) from heat exchanger (7).
• Remove the retaining screws (3) of the condensate trap (4).
The condense trap will contain water, lift taking care not to spill
the water.
• Remove the condensate trap (4) using the clips (5).
• IMPORTANT: Partially fill the condensate trap with water before
replacing. Start the siphon (1) and fill with water.
MAINTENANCE