- 33 -
Code Parameter
Unit
Description
factory
setting
Modifiable
parameter
d.43 Heating curve
K
See the instructions for the external sensor connected to the
appliance.
1.2
yes
d.45 Heating curve base
°C
20
yes
The following menus are displayed if an outdoor sensor (not supplied) is installed on the appliance.
d.47 Exterior temperature
°C
Display the temperature measured by the external sensor.
-
no
d.62 Night-time offset
°C
Choice of lowering the setting between night (COMFORT period on the
room thermostat) and night (ECO period on the room thermostat).
Select a value between 0 and 31°C.
0
yes
d.67 Time remaining before the end of the
anti-cycle in heating mode.
min. Display the time remaining before the end of the anti-cycle.
-
no
d.71 Maximum temperature setting for
heating outlet
°C
Select a value between 50°C and 80°C.
75
yes
d.85 Minimum heating power
kW
Choose a value:
8 to 30 kW
8
yes
d.90 Detection of eBUS controller
-
0 = Not detected
1 = Detected
-
no
d.94 Reinitialise fault list
-
This function is used to clear the fault list on the appliance.
0 = No
1= Reset fault list
0
yes
13.2.2
After Sales Service settings
• Press
the
button for more than 7 seconds
to access the
configuration menu. The screen displays "0".
• Press or button
of the Domestic hot water temperature
controls and enter the After Sales Service password.
• Press
to validate. The screen displays the parameter
"00" and its value "XX”.
• Press or button
of the Domestic hot water temperature
controls to access the parameter to modify.
• Press or button
of the Heating temperature controls to
modify the value of the parameter.
• Repeat the process for each parameter modified.
• Press
the
button for more than 3 seconds
to exit the
configuration menu.
INSTALLATION