Code Parameter
Unit
Description
factory
setting
Modifiable
parameter
d.09 Flow temperature set point from external eBus control
°C
External eBus set value.
-
no
d.10 Heating pump status
-
0 = off
1 = on
-
no
d.16 Current state of the 24V room thermostat
°C
0 = open (no heating),
1 = closed (heating mode)
-
no
d.17 Flow or Return temperature monitoring
°C
Temperature regulation on flow (radiator) or return
(under-floor heating) temperature sensor.
0
yes
d.22 DHW demand active (tapping)
-
0 = off
1 = on
-
no
d.23 Central heating mode
-
0 = CH not available (summer mode)
1 = CH available (winter mode)
-
no
d.33 Speed setpoint of fan
rpm
Fan speed is displayed between 0 and 99.
Multiply the displayed value by 100.
-
no
d.44 Digitalized ionisation voltage
V
Display the digitalized ionisation voltage
-
no
d.68 Unsuccessfull ignitions at first attempt
-
Display the number of unsuccessfull ignitions at first
attempt.
-
no
d.69 Unsuccessfull ignitions at second attempt
-
Display the number of unsuccessfull ignitions at
second attempt.
-
no
d.80 Operating hours in heating mode
h
Display the number of operating hours in heating
mode. Multiply the displayed value by 100.
-
no
d.81 Operating hours in domestic hot water mode
h
Display the number of operating hours in domestic hot
water mode. Multiply the displayed value by 100.
-
no
d.82 Number of burner starts in heating mode
-
Display the number of burner starts in heating mode.
Multiply the displayed value by 100.
-
no
d.83 Number of burner starts in DHW mode
-
Display the number of burner starts in DHW mode.
Multiply the displayed value by 100.
-
no
d.93 Device Specific Number
-
Select the product code of the appliance:
31
yes
d.96 Factory reset
-
All parameters stored in EEPROM (main board +
appliance interface) are reset to factory settings if
this function is activated.
0 = deactivated
1 = activated
0
yes