Technical data, 5 ultracom, 35 store – Glow-worm Ultracom2 35 Store User Manual
Page 10

0020112185_PROTO_13 - 01/11 - Glow-worm
- 8 -
TECHNICAL DATA
5 Ultracom
2
35 Store
Boiler, type C13, C33, C43
Description
Unit
35 Store
Gas category
ll
2H3P
SEDBUK 2005 rating
%
NA
SEDBUK 2009 rating
%
NA
Heating
G20
Maximum heating input power
kW
30.6
Minimum heating output power
at 80/60°C (P min.)
kW
8.5
Maximum heating output power
at 80/60°C (P max.)
kW
30
Minimum heating output power
at 50/30°C (P min.)
kW
9.3
Maximum heating output power
at 50/30°C (P max.)
kW
32.5
PCI Efficiency max heating power
at 80/60°C
%
97.9
PCI Efficiency max heating power
at 50/30°C
%
106.3
Efficiency at part load (30%) on PCI
at 40°C/30°C
%
108.6
Efficiency level according to the European
Directive 92/42
-
Condensing
Minimum calorific rate (Q min.)
kW
8.7
Maximum calorific rate (Q max.)
kW
30.6
Minimum heating flow rate
l/h
400
Minimum heating temperature
°C
10
Maximum heating temperature
°C
80
Content of heating expansion vessel
l
12
gallons
2.64
Heating expansion vessel preset pressure
bar
0.75
psi
10.9
Max. capacity of the installation at 75°C
l
220
Heating safety valve preset pressure (PMS)
bar
3
MPa
0.3
Domestic Hot Water
G20
Minimum DHW output power (P min.)
kW
8.7
Maximum DHW output power (P max.)
kW
35.7
Min. calorific rate (Q min)
kW
8.7
Maximum calorific rate (Q max.)
kW
35.7
Minimum DHW temperature
°C
45
Maximum DHW temperature
°C
65
Specific flow rate (∆T of 35 K)
l/min
19.7
Specific flow rate according to EN 625
l/min
NA
Level of sanitary confort
EN 13203
-
***
Flow rate operating threshold
l/min
0.1
High capacity tank
l
42
Water flow limitor
l/min
16
Safety valve, maximum working pressure
(PMW)
bar
10
psi
145
Minimum inlet water pressure
bar
0.3
psi
4.3
Maximum inlet water pressure (*)
bar
10
psi
145
Description
Unit
35 Store
Maximum temperature hot water safety
valve
°C
90
Maximum pressure hot water safety valve
bar
10
psi
145
(*) For a supply pressure above 3 bar, it is recommended that you install
a pressure reducer.
Description
Unit
35 Store
Combustion
G20
Fresh air flow rate (1013 mbar -0°C)
m
3
/h
45.7
Flue gas
flow rate at Pmin.
g/s
4
Flue gas
flow rate at Pmax.
g/s
13.8
Flue gas
flow rate in hot water mode
g/s
16
Flue gas
temperature at Pmin. 80°C/60°C
°C
72.4
Flue gas
temperature at Pmin. 50°C/30°C
°C
47.4
Flue gas
temperature at Pmax. 80°C/60°C
°C
77.2
Flue gas
temperature at Pmax. 50°C/30°C
°C
55.8
Flue gas
temperature in hot water mode
(with hot water temperature of 50°C)
°C
81
Value of combustion products (measured at nominal calorific rate and
with G20 reference gas, in heating):
CO
ppm
NA
mg/
kWh
8
CO
2
%
9.2
Weighted Nox
ppm
22.6
mg/
kWh
39.8
Appliance NOx class
5
Electrical
Electrical supply
V/Hz
230/50
Standby mode electrical power
W
6
Operational mode electrical power (Max)
W
178
Intensity
A
0.75
Internal fuse rating on main PCB
A
2
Index of electrical protection
(EN 60529)
IPX4D
Electrical classification
I
Description
Unit
35 Store
Gas connection Ø O.D.
mm
15 (copper)
Heating flow and return connection Ø O.D.
mm
22 (copper)
Domestic Hot Water connection Ø O.D.
mm
22
(copper)
Safety valve discharge connection Ø O.D.
mm
22
(copper)
TECHNICAL DATA