Mportant – EXFO FOT-930 Multifunction Loss Tester User Manual

Page 58

background image

Performing Automated IL/ORL/Length Measurements (F

AS

T

ES

T

)

50

FOT-930

Referencing Units for

F

AS

T

ES

T

To perform a side-by-side reference:
1.
On the master unit (the one initiating the

test), press F

AS

T

ES

T.

2. In the Ref. Type list, select the Side-by-side

reference type, then press Enter. An
illustration of the connection is shown with
previous reference values (if any).

3. Connect both units through their F

AS

T

ES

T ports, using two reference

patchcords and a bulkhead adapter.

4. Press Take Reference (F1/F2 key). After a few seconds, the unit

displays new reference values for each wavelength on both units. If
values are not acceptable, try to clean connectors and repeat this step.

5. Disconnect the two patchcords from the bulkhead only and connect

them to the fiber under test (using bulkhead adapters or the system
patch panels).

I

MPORTANT

You can turn off the unit without losing the reference.

If you disconnect the patchcords from the F

AS

T

ES

T ports, you

must take a new reference.

Reference

patchcord

Bulkhead

adapter

Reference

patchcord