beautypg.com

Data editing, Chapter 5, Data editing overview – Datalogic Scanning QUICKSCAN QS6500BT User Manual

Page 75

background image

Product Reference Guide

5-1

Chapter 5

Data Editing

Data Editing Overview

When a bar code is scanned, additional information can be sent to the
host computer along with the bar code data. This combination of bar
code data and supplementary user-defined data is called a “message
string.” The features in this chapter can be used to build specific
user-defined data into a message string.

There are several types of selectable data characters that can be sent
before, after, and even between scanned data. You can specify if they
should be sent with all symbologies, or only with specific symbologies.

Figure 5-1

shows the available elements you can add to a message string:

Figure 5-1. Breakdown of a Message String

CAUTION

It is not recommended to use these features with IBM
46xx or IBM interfaces.

Prefix

00 - 22 Characters (ASCII)

Sufffix

Symbology

ID

ID

Preamble

Postamble

Bar Code Data

Code Length

Insert Groups

Code Length Transmission: A number of data
digits can be transmitted before the code data.
The total length of the bar code is the number
of characters of bar code data without truncated
leading or ending digits.

Data Groups 1, 2, 3 and 4: Can be
variably inserted into positions within the
bar code data itself. One ASCII character
per Data Group, with character
selectable from 00 (none) to 63.

00 - 22 Characters (ASCII)

Code ID Transmission: Enable
this option to transmit the code
ID. See page ?.

Symbology Name: This function is used to identify and display the
scanned bar code's symbology (from among any of the symbologies
readable by the imager). When enabled, the code name
(symbology) will be transmitted before the bar code data.