Codabar — continued, Code i.d. selection – Datalogic Scanning QUICKSCAN QS6500BT User Manual
Page 207
Codabar
Product Reference Guide
6-119
Codabar — continued
Code I.D. Selection
The Code I.D. for this symbology consists of one or two user-selectable
ASCII characters. It can be appended previous to or following the trans-
mitted Codabar bar code data depending on how this feature is enabled.
Example: Setting the Codabar Code I.D.
To configure this feature:
1. Determine which character(s) you would like to use to represent
the Codabar symbology. Reference
Appendix A, ASCII Conversion
Chart
to find the corresponding hex values for your chosen charac-
ter(s). In this example we’ll set a Code I.D. of “%” (the percent
sign) to represent Codabar. The value from the table correspond-
ing to ‘%’ is 25. This value will be used in a step to follow.
2. Scan the START bar code
3. Scan the SET CODABAR CODE I.D. bar code.
4. Turn to
Appendix B, Alpha-Numeric Pad
and scan the bar codes ‘2’
and ‘5’ (the value determined in an earlier step to represent ‘%’).
5. Scan the SET bar code to accept the digits scanned.
6. Turn to the
Data Editing
chapter and scan the CODE ID POSI-
TION: BEFORE BAR CODE DATA label.
7. Scan the END bar code to exit Programming Mode.
8. The resulting message string for scanned Codabar labels would
appear as follows:
Scanned bar code data:
0123456789123
Resulting message string output: %0123456789123
NOTE
Features configured using the
Data Editing
chapter are
universal and will affect all symbologies.