Code I.D. Selection

The Code I.D. for this symbology consists of one or two user-selectable
ASCII characters. It can be appended previous to or following the trans-
mitted Code 93 bar code data depending on how this feature is enabled.

Example: Setting the Code 93 Code I.D.

To configure this feature:

1. Determine which character(s) you would like to use to represent

the Code 93 symbology. Reference

Appendix A, ASCII Conversion

Chart

to find the corresponding hex values for your chosen charac-

ter(s). In this example we’ll set a Code I.D. of “&” to represent
Code 93. The value from the table corresponding to ‘’&’ is 26.
This value will be used in a step to follow.

2. Scan the START bar code

3. Scan the SET CODE 93 CODE I.D. bar code.

4. Turn to

Appendix B, Alpha-Numeric Pad

and scan the bar codes ‘2’

and ‘6’ (the value determined in an earlier step to represent ‘&’).

5. Scan the SET bar code to accept the digits scanned.

6. Turn to the

Data Editing

chapter and scan the CODE ID POSI-

TION: BEFORE BAR CODE DATA label.

7. Scan the END bar code to exit Programming Mode.

8. The resulting message string for scanned Code 93 labels would

appear as follows:

Scanned bar code data:

0123456789123

Resulting message string output: &0123456789123