Rss expanded — continued, Code i.d. selection – Datalogic Scanning QUICKSCAN QS6500BT User Manual
Page 140
Symbologies
6-52
QuickScan
®
QS6500/QS6500 BT
RSS Expanded — continued
Code I.D. Selection
The Code I.D. for this symbology consists of one or two user-selectable
ASCII characters. It can be appended previous to or following the trans-
mitted RSS Expanded bar code data depending on how this feature is
enabled.
Example: Setting the RSS Expanded Code I.D.
To configure this feature:
1. Determine which character(s) you would like to use to represent
the RSS Expanded symbology. Reference
Appendix A, ASCII Con-
version Chart
to find the corresponding hex values for your chosen
character(s). In this example we’ll set a Code I.D. of “RX” to repre-
sent RSS Expanded. The value from the table corresponding to
‘’R’ is 52 and the value for ‘X’ is 58. These values will be used in a
step to follow.
2. Scan the START bar code
3. Scan the SET RSS Expanded CODE I.D. bar code.
4. Turn to
Appendix B, Alpha-Numeric Pad
and scan the bar codes ‘5’
and ‘2’ (the value determined in an earlier step to represent ‘R’).
Then scan the bar codes ‘5’ and ‘8’ (hex equivalent for ‘X’).
5. Scan the SET bar code to accept the digits scanned.
6. Turn to the
Data Editing
chapter and scan the CODE ID POSI-
TION: BEFORE BAR CODE DATA label.
7. Scan the END bar code to exit Programming Mode.
8. The resulting message string for scanned RSS Expanded labels
would appear as follows:
Scanned bar code data:
0123456789123
Resulting message string output: RX0123456789123
NOTE
Features configured using the
Data Editing
chapter are
universal and will affect all symbologies.