Code 16k — continued, Code i.d. selection – Datalogic Scanning QUICKSCAN QS6500BT User Manual

Page 262

background image

Symbologies

6-174

QuickScan

®

QS6500/QS6500 BT

Code 16K — continued

Code I.D. Selection

The Code I.D. for this symbology consists of one or two user-selectable
ASCII characters. It can be appended previous to or following the trans-
mitted Code 16K bar code data depending on how this feature is
enabled.

Example: Setting the Code 16K Code I.D.

To configure this feature:

1. Determine which character(s) you would like to use to represent

the Code 16K symbology. Reference

Appendix A, ASCII Conversion

Chart

to find the corresponding hex values for your chosen charac-

ter(s). In this example we’ll set a Code I.D. of “C” to represent
Code 16K. The value from the table corresponding to ‘’C’ is 43.
This value will be used in a step to follow.

2. Scan the START bar code

3. Scan the SET Code 16K CODE I.D. bar code.

4. Turn to

Appendix B, Alpha-Numeric Pad

and scan the bar codes ‘4’

and ‘3’ (the value determined in an earlier step to represent ‘C’).

5. Scan the SET bar code to accept the digits scanned.

6. Turn to the

Data Editing

chapter and scan the CODE ID POSI-

TION: BEFORE BAR CODE DATA label.

7. Scan the END bar code to exit Programming Mode.

8. The resulting message string for scanned Code 16K labels would

appear as follows:

Scanned bar code data:

0123456789123

Resulting message string output: C0123456789123

NOTE

Features configured using the

Data Editing

chapter are

universal and will affect all symbologies.