beautypg.com

Industrial 2 of 5 — continued, Minimum/maximum code length – Datalogic Scanning QUICKSCAN QS6500BT User Manual

Page 189

background image

Industrial 2 of 5

Product Reference Guide

6-101

Industrial 2 of 5 — continued

Minimum/Maximum Code Length

Many symbologies have their own maximum and minimum code
length, which can be set to qualify data entry. The length is defined as
the actual bar code data length to be sent. Labels with lengths below the
minimum or above the maximum will be rejected. If the maximum code
length is set to zero, the global maximum is in effect. If the minimum
code length is set to zero, the global minimum is in effect.

NOTE

Ensure that the minimum length setting is not greater
than the maximum length setting; otherwise, all the
labels of the symbology will be unreadable. You can set
the same value for both minimum and maximum length
to force decoding of only bar codes of a certain length.

START

MODE

BARCODE

Set Maximum

Length

DEFAULT SETTING FOR THIS FEATURE: 0 (00 Hex)

Set Minimum

Length

DEFAULT SETTING FOR THIS FEATURE: 0 (00 Hex)

SET