General Features

3-16

QuickScan

®

QS6500/QS6500BT

Global Features

Global Minimum Code Length

Global minimum length can be set to qualify data entry. The length is
defined as the actual bar code data length to be sent. bar code labels with
lengths exceeding these limits will be rejected. Ensure that the mini-
mum-length setting is no greater than the maximum-length setting; oth-
erwise, the labels of the symbology will not be readable. In particular,
you can set the same value for both minimum and maximum lengths to
force decoding of only fixed-length bar codes. This setting has no effect
on certain symbologies of fixed length.

START

MODE

BARCODE

Global Minimum length can be set from 0 to 255. To
set this feature, scan the “START” bar code above to
place the unit in Programming Mode, then the “Set
Global Minimum Length,” followed by the digits from
the Alphanumeric table in

Appendix B, Alpha-

Numeric Pad

representing your desired minimum

length. Accept your selection by scanning the “SET”
bar code below and finally, exit programming mode by
scanning the “END” barcode below.

DEFAULT SETTING FOR THIS FEATURE: 4

Set Global

Minimum

Length

SET

END