beautypg.com

Uk-plessey — continued, Code i.d. selection – Datalogic Scanning QUICKSCAN QS6500BT User Manual

Page 240

background image

Symbologies

6-152

QuickScan

®

QS6500/QS6500 BT

UK-Plessey — continued

Code I.D. Selection

The Code I.D. for this symbology consists of one or two user-selectable
ASCII characters. It can be appended previous to or following the trans-
mitted UK/Plessey bar code data depending on how this feature is
enabled.

Example: Setting the UK/Plessey Code I.D.

To configure this feature:

1. Determine which character(s) you would like to use to represent

the UK/Plessey symbology. Reference

Appendix A, ASCII Conversion

Chart

to find the corresponding hex values for your chosen charac-

ter(s). In this example we’ll set a Code I.D. of “@” to represent
UK/Plessey. The value from the table corresponding to ‘’@’ is 40.
This value will be used in a step to follow.

2. Scan the START bar code

3. Scan the SET UK/PLESSEY CODE I.D. bar code.

4. Turn to

Appendix B, Alpha-Numeric Pad

and scan the bar codes ‘4’

and ‘0’ (the value determined in an earlier step to represent ‘@’).

5. Scan the SET bar code to accept the digits scanned.

6. Turn to the

Data Editing

chapter and scan the CODE ID POSI-

TION: BEFORE BAR CODE DATA label.

7. Scan the END bar code to exit Programming Mode.

8. The resulting message string for scanned UK/Plessey labels would

appear as follows:

Scanned bar code data:

0123456789123

Resulting message string output: @0123456789123

NOTE

Features configured using the

Data Editing

chapter are

universal and will affect all symbologies.