background image

Red Clip

on Positive

Terminal

attery

Charger

FIGURE 15.

17. The battery can be slow charged (do not fast

charge) at a maximum bench rate of 1.4 am­
peres until the specific gravity reading is
1.260-1.280. Charge for a minimum of 2 hours

and a maximum of 8 hours.

^ WARNING \

The battery charger provided is

specially designed for the battery in

this unit. Do not use any other

charger. A charging rate in excess
of the above specifications will
buckle and warp the positive plates

and/or perforate the separators.

To Attach the Battery Charger:

1. Attach the red clip on the charger to the

positive terminal.

2. Attach the black clip on the charger to the

negative terminal.

3. Plug the other end of the battery charger into

a standard household 110 A.C. outlet.

To Remove the Battery Charger:

1. Unplug the charger from the 110 A.C. outlet.

2. Remove the black clip from the negative ter­

minal.

3. Remove the red clip from the positive ter­

minal.

WARNING

Failure to follow the above pro­

cedure when charging a battery can
cause the gases in the battery to
explode.

NOTE

Charging rate after battery has been
put into operation: The battery is to
be charged with the charger pro­
vided, for a period of 14-16 hours.

NO LONGER THAN 30 HOURS.

A

CAUTION

After battery has been in service,
add only distilled water. DO NOT
ADD ACID.

18.Slide the rubber boot over the positive ter­

minal. See figure 16.