12

VALVE TEST

Valve Test is used to verify steering is directed cor-
rectly and to determine the amount of time required to
move the steering wheels from fully left to fully right.
Use the Plus

or Minus

keys to adjust the left,

right, and off values. The Plus

key turns to the

right, the Minus

key turns to the left, and pressing

either one again will stop the turn. Press the Enter
key to accept the changes and advance to the Dis-
play Setup Mode.

Once the fi nal setting has been entered and saved,
the screen will return to the initial CL230BP Assisted
Steering Screen. If no additional changes are re-
quired, press the Escape

key to exit to Operation

Mode.

Tilt Gyro Setup Mode

NOTE: If a Steering Control Module (SCM) or a

Tilt Gyro Module are not connected to
the system, Tilt Compensation Setup
Mode will not be displayed. Proceed to
the next section.

NOTE: If a Tilt Gyro Module is connected but

an SCM is not, the following screen will
be displayed instead of the standard Tilt
Gyro screens. The screen will display the
software version.

Tilt corrected GPS positions provide
improved guidance performance in
hilly terrain. To provide accurate tilt
correction, the operator must cali-
brate the Steering Control Module
(SCM). The CL230BP will detect if
an SCM is connected. If connected,
tilt calibration can be performed.

Press the Setup Mode

key until the initial Tilt Cali-

bration Setup Mode screen is displayed.

Press the Enter

key to save the set-

ting and advance the screen. Press
the Escape

key to exit from Setup

Mode without saving any changes.
After 10 seconds of inactivity, Setup
Screens will time out (changes will
be saved). The CL230BP will return
to Operation Mode.

TILT GYRO

The Tilt Gyro Module allows for tilt
correction. A Tilt Correction On/Off
page will be displayed. If the page
displays an empty checkbox, the Tilt
Calibration screens will not be avail-
able. If the box is checked, the Tilt
Calibration screens will be accessed.
If the box is checked and a calibra-
tion has already been performed,
press the Escape

key to avoid

performing an additional calibration
procedure.