Appendix b - unit specifications, Isobus job computer : ic18 spreader european, Calibrations – TeeJet IC18 SPREADER JOB COMPUTER User Manual
Page 30: Alarm configurations, User interface, Pulses per volume, Implement speed sensor
![background image](/manuals/713551/30/background.png)
26
www.teejet.com
OVER
VIE
W
SE
TUP
APPENDIX
GE
TTING ST
AR
TED
OPER
ATION
ISOBUS Job Computer : IC18 Spreader European
Calibrations
Pulses per Volume
Description
Factory Setting
Range
User Setting
Pulses per Volume
0.0 /ft
3
0.0 /cm
3
0.0 - 5000 /ft
3
0.0 - 1500.0 /cm
3
Implement Speed Sensor
Description
Factory Setting
Range
User Setting
Pulses per Distance
0 ft
0 m
0 - 30000 /300 ft
0 - 40000 /100 m
Alarm Configurations
Description
Factory Setting
Range/Options
User Setting
Amount Remaining Alarm On/Off
Off
On
Off
Amount Remaining Trigger Level
0 lb
0 kg
0 - 9000 lb
0 - 4500 kg
CAN Speed Source Timeout
4 sec
0 - 999 sec
Active Trip Count Information
Off
On
Off
Spinner RPM Alarm On/Off
Off
On
Off
Spinner RPM Trigger Level
0 RPM
0 - 9999 RPM
USER INTERFACE
Description
Factory Setting
Options
User Setting
Use Perferred VT
Off
Off
On
APPENDIX B - UNIT SPECIFICATIONS
Dimensions
19.05 x 18.42 x 6.03 cm
Weight
0.644kg
Connector
30 position Cinch pins. A1-K3
30 position Cinch pins. L1-Y3
Environmental
Operating
-40 to +85°C
Humidity
90% non-condensing
Input/Output
ISO 11783 (ISOBUS)
Power Requirement
<9 watts @12 VDC